Radially Split Single Stage Overhung Pumps (API Class OH2)
Heavy duty construction is full compliance with API610
- BACK PULL-OUT CONSTRUCTION
Maintenance can be carried out without disturbing the driver or the suction and discharge pipings. - Centerline support
The casing is of centerline support design for eliminating the effect of the thermal expansion under the high temperature operating conditions. - Seal chamber
Seal chamber dimensions conform to API 682 and API610 standards. All popular dual seals can be installed without having to make any modification. - Bearing cooling
Forced air cooling by cooling fan or water jacket cooling is standard for the high temperature application.

|
|
|
|
|
|
|
|
|
|
|
|
|
|
Coverage - 50Hz |
![]() |
Coverage - 60Hz |
![]() |
| (*) In addition to above-mentioned chart, we will provide the best design for your application. | |
| Max. Flow Rate up to 1500m3/h(6600 US GPM) |
| Max. Diff. Head up to 400 m(1310 feet) |
| Max. Operation Temperature up to 400°C(752°F) |
| Pressure Rating over 4 MPa(600 PSIG) |